Anesthesia Machine ZAM-A16

Anesthesia Machine ZAM-A16

Anesthesia machine ZAM-A16 include pressure restriction and volume control. The device contains a 10.4-inch TFT LCD display screen, an audio and video alarm system, and a high-precision flowmeter. In an emergency, the device is powered by an internal backup battery. It can also be modified to meet the needs of the patient and offers a number of ventilation methods, including IPPV, A/C, PSV, PCV, SIMV, SIGH, and manual.

Ventilation Mode IPPV, A/C, PCV, PSV SIMV, SIGH, MANUAL
Ventilator Parameter Range a:11:{s:9:"Flowmeter";s:69:"O2 (0.1 – 10 L/min); N2O (0.1 – 10 L/min); AIR (0.1 – 10 L/min)";s:19:"Rapid Oxygen Supply";s:21:"35 L/min – 75 L/min";s:12:"Tidal Volume";s:19:"0.20 mL – 1500 mL";s:9:"Frequence";s:17:"1/min – 100/min";s:31:"Pressure triggering Sensitivity";s:39:"-20 cm H2O – 0 cm H2O (Based on PEEP)";s:4:"PEEP";s:23:"0 cm H2O – 30 cm H2O)";s:24:"Flow Trigger Sensitivity";s:22:"0.5 L/min – 30 L/min";s:4:"SIGH";s:23:"0 (off) 1/100 – 5/100";s:17:"Apnea Ventilation";s:20:"OFF, 5sec – 60 sec";s:21:"PC (Pressure Control)";s:22:"5 cm H2O – 60 cm H2O";s:5:"Limit";s:24:"20 cm H2O – 100 cm H20";}
Monitoring Parameter a:4:{s:9:"Frequence";s:19:"0 /min – 100 /min";s:6:"Volume";s:16:"0 mL – 2000 mL";s:2:"MV";s:21:"0 L/min – 100 L/min";s:20:"Oxygen Concentration";s:10:"15% - 100%";}
Alarm & Protection a:11:{s:22:"AC power failure Alarm";s:30:"Power failure or no connection";s:37:"Low Voltage alarm for back up battery";s:15:"< 11.3 ± 0.3 V";s:15:"No Tidal Volume";s:18:"≤ 5 mL within 6s";s:26:"Oxygen Concentration Alarm";s:34:"19% - 100% (HIGH); 18% - 99% (LOW)";s:21:"Airway Pressure Alarm";s:60:"20 cmH2O – 100 cm H2O (HIGH); 0 cm H2O – 20 cm H2O (LOW)";s:19:"Minute Volume Alarm";s:87:"Adult (5 L/min – 20 L/min); Child (1 L/min – 15 L/min) (HIGH); 0 – 10 L/min (LOW)";s:25:"Continuous Pressure Alarm";s:25:"(PEEP + 1.5 kPa) over 16s";s:19:"Suffocation Warning";s:37:"5s – 60s no spontaneous ventilation";s:28:"The Maximum Limited Pressure";s:10:"< 12.5 kPa";s:9:"Fan Error";s:14:"Show On Screen";s:14:"Oxygen Deficit";s:14:"Show On Screen";}
Working Condition a:4:{s:10:"Gas Source";s:12:"O2, N2O, AIR";s:8:"Pressure";s:19:"280 kPa – 600 kPa";s:7:"Voltage";s:13:"100 – 240 V";s:15:"Power Frequency";s:10:"50 / 60 Hz";}
Packing Size a:3:{s:24:"Dimensions (L × W × H)";s:22:"810 × 1060 × 1540 mm";s:10:"Net Weight";s:6:"124 Kg";s:12:"Gross Weight";s:6:"195 Kg";}
  • It is straightforward, secure, trustworthy, and simple to use
    Four static casters with self-locking mechanisms
    A 10.4-inch TFT LCD display
    multiple working modes
    Audio-video power failure and voltage alert system
    Vaporizer with temperature, pressure, and flow correction
    High precision flowmeter
    Integrated breathing circuit
  • Anesthesia machines are used in operating rooms, intensive care units (ICUs), and anesthesiology departments in the field of medicine and hospitals.

Anesthesia Machines

Enquiry Form