Benchtop pH meter  25-BPM103

Benchtop pH meter 25-BPM103

Benchtop pH meter comes with -2.000 to 20.000 pH range and is suitable for daily pH measurement, testing. 1 to 5 points push button calibration is performed using standard USA or NIST pH buffers & 1 point calibration to measure ORP. It offers automatic or manual temperature compensation mode of pH measurements. The pH meter with sleek design has easy to read backlit LCD screen which shows pH measurements & temperature simultaneously.

pH measurement range -2.000 to 20.000 pH
pH accuracy ± 0.002 pH
Calibration points 1-5 points
Calibration solutions USA, NIST, DIN or user defined
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration range ±200 mV
ORP calibration solutions mV & relative mV
Temperature compensation 0 to 100°C, 32 to 212°F
Compensation mode Manual or automatic
Stability conditions Low or high
Calibration due 0 to 31 days
memory Stores up to 500 data sets
Output USB communication interface
Connector BNC
Display LCD
Dimension (L*W*H) 210×188×60 mm
Weight 1.5 kg
Power DC5V using AC adapter, AC220V /50 Hz
  • pH Mode Features:
    Equipped with white backlit LCD display
    pH measurement range -2.000 to 20.000 pH
    1 to 5 points push button calibration to automatically identify pH buffer
    Automatic electrode slope display, helps the operator when to replace the sensor
    Automatic temperature compensation for accurate measured value over the entire range
    Universal BNC connector
    Built-in solution holder
    ORP Mode Features:
    ORP measurement range -1999.9 to 1999.9 mV
    Single point offset calibration to adjust the display value to a known standard
    Relative & absolute mV measurements for accurate ORP readings
    Common Features:
    Calibration due reminder informs operator to calibrate the meter regularly
    Stability indicator displays the status of current measurement
    Auto hold function freezes stable, final readings for better viewing and recording
    Manual temperature calibration to rectify the deviations in temperature
    Automatic temperature compensation for accurate measured value over the entire range
    Selectable temperature units (°C or °F) for different application requirements
    Expanded memory stores and recalls up to 500 readings
    Help message as an operational guide, helps users for quick access to the parameters
    Reset function automatically resumes all the setting back to factory default options
    Store data is transferrable into computer via USB communication interface
  • BNC pH Electrode
    Temperature probe
    pH buffer pouches (pH 4.01/7.00/10.01)
    USB cable
    Dc5V power adapter
  • pH Electrode
    pH buffer pouches (pH 4.01/6.98/9.18) NIST
    pH buffer pouches (pH 4.01/7.00/10.01) USA
    Temperature probe
  • The benchtop pH meter can be used for daily measurement of pH, ORP & temperature at schools, colleges & research laboratories & water testing plants.

Benchtop Conductivity Meter

Benchtop conductivity meter 25-BCM100

  • Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy : ± 1 % F.S.

Benchtop conductivity meter 25-BCM101

  • Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy : ± 1 % F.S.

Benchtop Dissolved oxygen meter

Benchtop Dissolved oxygen meter 25-BDO100

  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg / L

Benchtop Dissolved oxygen meter 25-BDO101

  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.2 mg / L

Benchtop Ion Meter

Benchtop Water hardness meter

Benchtop Water hardness meter 25-BWH100

  • Water hardness range : 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy : ± 1 % F.S.

Conductivity Tester

Pocket Conductivity tester 25-PCT100

  • Conductivity measurement range : 1.0 to 199.9 µS/cm
  • Type of conductivity : Low range conductivity

Pocket Conductivity tester 25-PCT101

  • Conductivity measurement range : 10 to 1999 µS/cm
  • Type of conductivity : Mid-range conductivity

Pocket Conductivity tester 25-PCT102

  • Conductivity measurement range : 0.1 to 19.99 mS/cm
  • Type of conductivity : High range conductivity

Dissolved Oxygen tester

Pocket Dissolved oxygen tester 25-PDO100

  • Dissolved oxygen range : 0.0 to 20.0 mg/L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg/L

Multi-parameter water quality Analyzer

Multi parameter water quality analyzer 25-MWA100

  • COD : a:11:{s:23:"COD determination range";s:16:"2 to 10000 mg/ L";s:24:"COD measurement accuracy";s:61:"COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %";s:27:"COD minimum detection limit";s:9:"0.1 mg/ L";s:20:"COD measurement time";s:10:"20 minutes";s:17:"COD repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:0:"";s:44:"Consumables for colorimetric COD measurement";s:30:"Colorimetric tubes and Cuvette";s:33:"COD reactor digestion temperature";s:14:"165 ± 0.5°C";s:26:"COD reactor digestion time";s:6:"10 min";s:33:"COD reactor time setting switches";s:5:"3 pcs";s:26:"Anti-chlorine interference";s:27:"(Cl) < 1000 mg/ L No effect";}
  • Ammonia nitrogen : a:8:{s:36:"Ammonia nitrogen determination range";s:16:"0.02 to 60 mg/ L";s:37:"Ammonia nitrogen measurement accuracy";s:11:"≤ ± 10 %";s:40:"Ammonia nitrogen minimum detection limit";s:10:"0.01 mg/ L";s:33:"Ammonia nitrogen measurement time";s:16:"10 to 15 minutes";s:30:"Ammonia nitrogen repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:0:"";s:57:"Consumables for colorimetric ammonia nitrogen measurement";s:30:"Colorimetric tubes and Cuvette";s:46:"Ammonia nitrogen reactor time setting switches";s:5:"3 pcs";}

Multi parameter water quality analyzer 25-MWA101

  • COD : a:11:{s:23:"COD determination range";s:15:"5 to 5000 mg/ L";s:24:"COD measurement accuracy";s:61:"COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %";s:27:"COD minimum detection limit";s:9:"0.1 mg/ L";s:20:"COD measurement time";s:10:"20 minutes";s:17:"COD repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:6:"12 pcs";s:44:"Consumables for colorimetric COD measurement";s:30:"Colorimetric tubes and Cuvette";s:33:"COD reactor digestion temperature";s:14:"165 ± 0.5°C";s:26:"COD reactor digestion time";s:6:"10 min";s:33:"COD reactor time setting switches";s:5:"3 pcs";s:26:"Anti-chlorine interference";s:27:"(Cl) < 1000 mg/ L No effect";}
  • Ammonia nitrogen : a:8:{s:36:"Ammonia nitrogen determination range";s:16:"0.02 to 30 mg/ L";s:37:"Ammonia nitrogen measurement accuracy";s:11:"≤ ± 10 %";s:40:"Ammonia nitrogen minimum detection limit";s:10:"0.01 mg/ L";s:33:"Ammonia nitrogen measurement time";s:16:"10 to 15 minutes";s:30:"Ammonia nitrogen repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:6:"20 pcs";s:57:"Consumables for colorimetric ammonia nitrogen measurement";s:30:"Colorimetric tubes and Cuvette";s:46:"Ammonia nitrogen reactor time setting switches";s:5:"3 pcs";}

ORP tester

Pocket ORP tester 25-POT100

  • Sensor type : Platinum sensor
  • Connector : 6 pin

Pocket ORP tester 25-POT101

  • Connector : BNC
  • ORP measurement range : (-999) to 999 mV

pH Tester (POCKET)

Portable dissolved oxygen meter

Portable Dissolved oxygen meter 25-PDM100

  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg / L

Portable Dissolved oxygen meter 25-PDM101

  • Dissolved oxygen range : 0.0 - 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.2 mg / L

Portable Multi Parameter Water Quality Meter

pH Meter (Portable)

Portable pH meter 25-PPM100

  • pH range : (-2.00) to 16.00 pH
  • pH accuracy : ± 0.01 pH

Portable pH/ORP meter 25-PPM101

  • pH range : (-2.00) to 20.00 pH
  • pH accuracy : ± 0.002 pH

Portable water hardness meter

Portable water hardness meter 25-PHM100

  • Water hardness range : 0.05 mmol / L - 0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy : ± 1 % F.S.

Salinity Tester

Pocket Salinity tester 25-PST100

  • Salinity measurement range : 0.00 to 10.00 ppt
  • Salinity accuracy : ± 1 % F.S

Pocket Salinity tester 25-PST101

  • Salinity measurement range : 0.00 to 80.00 ppt
  • Salinity accuracy : ± 1 % F.S

TDS tester

Turbidity Meter

Enquiry Form