Gas Chromatography 30-GCG100

Gas Chromatography 30-GCG100

Gas chromatography system comes with different detectors and each detector individually controls the temperature of the system. This gas chromatography comes with packed column injectors, split/split less injectors, capillary and cool-on column. It is possible to achieve lower limit of detection using these unique injector system. It gives accurate, high precision control, reliable results.

Chromatography column type Capillary and Packed column
Chromatography column length 100 to 500 mm
Chromatography column diameter 0.2 to 0.5 mm
Temperature operating range Higher than the room temperature of 5 ℃ to 450 ℃
Maximum programmed heating speed 120 ℃/min
Programmed temperature steps 7 steps
Temperature setting precision 1 °C
Programmed heating rate 0.1 to 120 °C/min (increment of 0.1 °C)
Furnace dimension 280 × 300 ×180 mm
Injectors Packed column injectors, split/split less capillary column injectors, cool on-column injectors
Detectors Following detectors can be selected as per the requirement
FID Maximum temperature control: 400 °C
LOD: ≤ 5 × 1012 g / s [n - C16]
Linear dynamic range: ≥ 107
Drift: ≤ 5 × 10-13 A / 30 min
Noise: ≤ 2 × 10-13 A
TCD Maximum temperature control: 400 °C
LOD: ≥ 10000 mv.ml / mg [n - C16]
Linear dynamic range: ≥ 104
Drift: ≤ 10 µV / 30 min
Noise: ≤ 20 µA
FPD Maximum temperature control: 250 °C
LOD: ≤2×10-13 g / s (P), ≤ 5 × 10-11 g / s (S)
Linear dynamic range: ≥ 103 (P), ≥ 102 (S)
Drift: ≤ 4 × 10-11 A / 30 min
Noise: ≤ 2 × 10-12 A
ECD Maximum temperature control: 350 °C
LOD: ≤ 1 × 10-14 g / ml (y - 666)
Linear dynamic range: ≥ 104
Drift: ≤ 5 µV / 30 min
Noise: ≤ 20 µA
NPD Maximum temperature control: 400 °C
LOD: ≤ 5 × 10-13 g / s (P), ≤ 1 × 1012 g / s (N)
Linear dynamic range: ≥ 103 (P), ≥ 103 (N)
Drift: ≤ 2.5 × 10-12A / 30 min
Noise: ≤ 4 × 10-13 A
PDHID LOD: ≤ 5 ppb
  • 7 steps temperature rising function
    LCD display to view test parameters
    Individual temperature controlling detectors
    Self-diagnosis, keyboard locking function
    Data storage during power off
    Different detectors with high stability and sensitivity for selection
    Stable and speedy program for furnace heating
    Unique injectors system for detection of lower limit
  • Used in the analysis of oil extraction and refining industry, petrochemical analysis, gas industry and in quality control of medicines, food and chemicals.

Ion Chromatography

Ion chromatograph system 30-ICG200

  • Ion Chromatographic Pump : a:6:{s:4:"Type";s:64:"High pressure and low pulse double plunger tandem advection pump";s:16:"Maximum pressure";s:13:"35 MPa (PEEK)";s:25:"Pressure display accuracy";s:11:"≤ 0.1 MPa";s:14:"Flow stability";s:91:"(0.2 to 0.5) ml/ min ≤ 3 %
    (0.5 to 1.0) ml/ min ≤ 2 %
    > 1.0 ml/ min 2 %
    ";s:10:"Flow range";s:22:"0.001 to 9.999 ml/ min";s:14:"Pressure pulse";s:8:"≤ 0.5%";}
  • Conductivity detector : a:16:{s:4:"Type";s:53:"Temperature Control and Bipolar Conductivity Detector";s:14:"Detection mode";s:30:"Bipolar conductivity detection";s:11:"Cell volume";s:11:"≤ 0.8 µL";s:15:"Detection range";s:18:"0 to 35000 µS/ cm";s:20:"Detection resolution";s:17:"≤ 0.0020 nS/ cm";s:14:"Output voltage";s:31:"- 6000 to +6000 mV (adjustable)";s:14:"Baseline noise";s:15:"≤ 0.05 % F.S.";s:14:"Baseline drift";s:18:"≤ 3 % FS/ 30 min";s:27:"Operating temperature range";s:43:"Room temperature +5 to 60°C (41 to 140°F)";s:32:"Controlling temperature accuracy";s:10:"± 0.01°C";s:16:"Maximum pressure";s:6:"10 MPa";s:12:"Linear range";s:7:"≥ 103";s:21:"Instruments linearity";s:9:"≥ 0.999";s:26:"Quantitative repeatability";s:9:"≤ 1.0 %";s:25:"Qualitative repeatability";s:9:"≤ 1.0 %";s:32:"Minimum detectable concentration";s:73:"Cl ≤ 0.0005 ug/ ml
    BrO3 ≤ 0.001 ug/ ml
    Li+ ≤ 0.001 ug/ ml";}

Ion chromatograph system 30-ICG201

  • Ion Chromatographic Pump : a:6:{s:4:"Type";s:64:"High pressure and low pulse double plunger tandem advection pump";s:16:"Maximum pressure";s:13:"35 MPa (PEEK)";s:25:"Pressure display accuracy";s:11:"≤ 0.1 MPa";s:14:"Flow stability";s:86:"(0.2 to 0.5) ml/ min ≤ 3 %
    (0.5 to 1.0) ml/ min ≤ 2 %
    > 1.0 ml/ min 2 %";s:10:"Flow range";s:22:"0.001 to 9.999 ml/ min";s:14:"Pressure pulse";s:8:"≤ 0.5%";}
  • Conductivity detector : a:16:{s:4:"Type";s:53:"Temperature Control and Bipolar Conductivity Detector";s:14:"Detection mode";s:30:"Bipolar conductivity detection";s:11:"Cell volume";s:11:"≤ 0.8 µL";s:15:"Detection range";s:18:"0 to 45000 µS/ cm";s:20:"Detection resolution";s:17:"≤ 0.0020 nS/ cm";s:14:"Output voltage";s:31:"- 6000 to +6000 mV (adjustable)";s:14:"Baseline noise";s:15:"≤ 0.05 % F.S.";s:14:"Baseline drift";s:18:"≤ 3 % FS/ 30 min";s:27:"Operating temperature range";s:43:"Room temperature +5 to 60°C (41 to 140°F)";s:32:"Controlling temperature accuracy";s:10:"± 0.01°C";s:16:"Maximum pressure";s:6:"10 MPa";s:12:"Linear range";s:7:"≥ 103";s:21:"Instruments linearity";s:9:"≥ 0.999";s:26:"Quantitative repeatability";s:9:"≤ 1.0 %";s:25:"Qualitative repeatability";s:9:"≤ 1.0 %";s:32:"Minimum detectable concentration";s:73:"Cl ≤ 0.0005 ug/ ml
    BrO3 ≤ 0.001 ug/ ml
    Li+ ≤ 0.001 ug/ ml";}

Gas Chromatograph Mass Spectrometer

Gas-Chromatograph-Mass Spectrometer 30-GMS100

  • Gas Chromatography Specifications : a:12:{s:8:"Model No";s:5:"GC-87";s:9:"Flow rate";s:16:"1 ~ 1.5 ml / min";s:17:"Maximum flow rate";s:11:"10 ml / min";s:17:"Inlet temperature";s:7:"450 °C";s:14:"Pressure range";s:11:"0 ~ 100 psi";s:12:"Heating rate";s:18:"Upto 120 °C / min";s:16:"Room temperature";s:17:"4 °C ~ 450 °C";s:21:"Pressure control mode";s:50:"Electronic pressure control ( Supports CV and CC )";s:10:"Split mode";s:18:"Split / split less";s:11:"Split ratio";s:8:"1000 : 1";s:23:"Temperature programming";s:22:"7 stages / 8 platforms";s:12:"Auto sampler";s:8:"Optional";}
  • Mass Spectrometry Specifications : a:12:{s:8:"Model No";s:5:"MS-89";s:10:"Mass range";s:14:"1.5 ~ 1000 amu";s:26:"Ion – source temperature";s:19:"100 °C ~ 350 °C";s:27:"GC-MS interface temperature";s:7:"450 °C";s:9:"Scan rate";s:16:"Upto 10000 amu/s";s:9:"Stability";s:21:"± 0.10 amu / 48 hrs.";s:25:"Filament emission current";s:11:"0 ~ 350 µA";s:27:"EI source ionization energy";s:13:"5 eV ~ 250 eV";s:10:"Resolution";s:15:"Unit resolution";s:8:"Detector";s:38:"High energy dynode electron multiplier";s:11:"Sensitivity";s:33:"Full scan ( S / N is ≥ 30 : 1 )";s:6:"Vacuum";s:31:"Turbo molecular pump ( 67 L/s )";}