Gas Chromatography 30-GCG101

Gas Chromatography 30-GCG101

Gas chromatography system is equipped with superior quality, high-precision electronic flow/ pressure control system. This gas chromatograph system has accurate tracking design and accurate programmed heating control system for the furnace temperature. Incorporated with safe and reliable functions of self-ignition and hydrogen leakage self-protection.

Chromatography column type Capillary or Packed column
Chromatography column length 100 to 300 mm
Chromatography column diameter 0.2 to 0.5 mm
Temperature operating range Higher than the room temperature of 5 °C to 450°C
Liquid nitrogen cold trap: -80 °C to 400 °C
Dry ice cold trap: -55 °C to 400 °C
Maximum programmed heating speed 120 °C/min
Programmed temperature steps 7 steps
Temperature setting precision 0.1 °C
Programmed heating rate 0.1 to 120 º C/min (increment of 0.1°C)
The longest method run time 999.99 min
Furnace dimension 280 × 300 ×180 mm
Heating area Six individual controlling heating areas
Maximum temperature in auxiliary heating area: 300 °C
Detectors Following detectors can be selected as per the requirement
FID Maximum using temperature: 450 °C
Minimum LOD: ≤ 2.5 pg C / s [n - C16]
Linear dynamic range: 107 (± 10 %)
Data collection frequency: Maximum 100 Hz
TCD Maximum using temperature: 400 °C
Minimum LOD: < 400 pg C3 H8 / ml(He)
Linear dynamic range: 105 (± 5 %)
Data collection frequency: Maximum 100 Hz
The design of monofilament TCD and Micro-ECD
FPD Maximum using temperature: 250 °C
Minimum LOD: < 4 pg S / sec, < 1 pg P/sec
Linear dynamic range: > 103 (S), > 104 (P)
Optional: 105 g S / g C, 106 g P / g C
ECD Maximum using temperature: 400 °C
Type of gas compensation detector: 5 % methane, argon, nitrogen
Minimum LOD: > 107 S, > 107 P
Linear dynamic range: 5 × 105
Data collection frequency: Maximum 100 Hz
Radioactive source: < 12 mCi 63 Ni
NPD Maximum using temperature: 450 °C
Minimum LOD: < 0.2 pg N / sec, < 0.2 pg P / sec
Minimum LOQ: < 3 pg / sec
Linear dynamic range: 105 N, 105 P
  • EPC controlled injector flow, column carrier flow and detector gas flow 7 steps temperature rising function
    LCD display to view test parameters
    Different detectors with high stability and sensitivity for selection
    Quick heating and cooling system
    Gas circuit technology with blowback function
    Adopted with imported valve configuration system
    Use of 8 digit auto injector
    Six individual controlling heating areas
  • Used in quality supervision of medicines, foods and chemicals, oil extraction and refining industry, petrochemical industry, electronic high-purity gas industry and scientific research institutes.

Ion Chromatography

Ion chromatograph system 30-ICG200

  • Ion Chromatographic Pump : a:6:{s:4:"Type";s:64:"High pressure and low pulse double plunger tandem advection pump";s:16:"Maximum pressure";s:13:"35 MPa (PEEK)";s:25:"Pressure display accuracy";s:11:"≤ 0.1 MPa";s:14:"Flow stability";s:91:"(0.2 to 0.5) ml/ min ≤ 3 %
    (0.5 to 1.0) ml/ min ≤ 2 %
    > 1.0 ml/ min 2 %
    ";s:10:"Flow range";s:22:"0.001 to 9.999 ml/ min";s:14:"Pressure pulse";s:8:"≤ 0.5%";}
  • Conductivity detector : a:16:{s:4:"Type";s:53:"Temperature Control and Bipolar Conductivity Detector";s:14:"Detection mode";s:30:"Bipolar conductivity detection";s:11:"Cell volume";s:11:"≤ 0.8 µL";s:15:"Detection range";s:18:"0 to 35000 µS/ cm";s:20:"Detection resolution";s:17:"≤ 0.0020 nS/ cm";s:14:"Output voltage";s:31:"- 6000 to +6000 mV (adjustable)";s:14:"Baseline noise";s:15:"≤ 0.05 % F.S.";s:14:"Baseline drift";s:18:"≤ 3 % FS/ 30 min";s:27:"Operating temperature range";s:43:"Room temperature +5 to 60°C (41 to 140°F)";s:32:"Controlling temperature accuracy";s:10:"± 0.01°C";s:16:"Maximum pressure";s:6:"10 MPa";s:12:"Linear range";s:7:"≥ 103";s:21:"Instruments linearity";s:9:"≥ 0.999";s:26:"Quantitative repeatability";s:9:"≤ 1.0 %";s:25:"Qualitative repeatability";s:9:"≤ 1.0 %";s:32:"Minimum detectable concentration";s:73:"Cl ≤ 0.0005 ug/ ml
    BrO3 ≤ 0.001 ug/ ml
    Li+ ≤ 0.001 ug/ ml";}

Ion chromatograph system 30-ICG201

  • Ion Chromatographic Pump : a:6:{s:4:"Type";s:64:"High pressure and low pulse double plunger tandem advection pump";s:16:"Maximum pressure";s:13:"35 MPa (PEEK)";s:25:"Pressure display accuracy";s:11:"≤ 0.1 MPa";s:14:"Flow stability";s:86:"(0.2 to 0.5) ml/ min ≤ 3 %
    (0.5 to 1.0) ml/ min ≤ 2 %
    > 1.0 ml/ min 2 %";s:10:"Flow range";s:22:"0.001 to 9.999 ml/ min";s:14:"Pressure pulse";s:8:"≤ 0.5%";}
  • Conductivity detector : a:16:{s:4:"Type";s:53:"Temperature Control and Bipolar Conductivity Detector";s:14:"Detection mode";s:30:"Bipolar conductivity detection";s:11:"Cell volume";s:11:"≤ 0.8 µL";s:15:"Detection range";s:18:"0 to 45000 µS/ cm";s:20:"Detection resolution";s:17:"≤ 0.0020 nS/ cm";s:14:"Output voltage";s:31:"- 6000 to +6000 mV (adjustable)";s:14:"Baseline noise";s:15:"≤ 0.05 % F.S.";s:14:"Baseline drift";s:18:"≤ 3 % FS/ 30 min";s:27:"Operating temperature range";s:43:"Room temperature +5 to 60°C (41 to 140°F)";s:32:"Controlling temperature accuracy";s:10:"± 0.01°C";s:16:"Maximum pressure";s:6:"10 MPa";s:12:"Linear range";s:7:"≥ 103";s:21:"Instruments linearity";s:9:"≥ 0.999";s:26:"Quantitative repeatability";s:9:"≤ 1.0 %";s:25:"Qualitative repeatability";s:9:"≤ 1.0 %";s:32:"Minimum detectable concentration";s:73:"Cl ≤ 0.0005 ug/ ml
    BrO3 ≤ 0.001 ug/ ml
    Li+ ≤ 0.001 ug/ ml";}

Gas Chromatograph Mass Spectrometer

Gas-Chromatograph-Mass Spectrometer 30-GMS100

  • Gas Chromatography Specifications : a:12:{s:8:"Model No";s:5:"GC-87";s:9:"Flow rate";s:16:"1 ~ 1.5 ml / min";s:17:"Maximum flow rate";s:11:"10 ml / min";s:17:"Inlet temperature";s:7:"450 °C";s:14:"Pressure range";s:11:"0 ~ 100 psi";s:12:"Heating rate";s:18:"Upto 120 °C / min";s:16:"Room temperature";s:17:"4 °C ~ 450 °C";s:21:"Pressure control mode";s:50:"Electronic pressure control ( Supports CV and CC )";s:10:"Split mode";s:18:"Split / split less";s:11:"Split ratio";s:8:"1000 : 1";s:23:"Temperature programming";s:22:"7 stages / 8 platforms";s:12:"Auto sampler";s:8:"Optional";}
  • Mass Spectrometry Specifications : a:12:{s:8:"Model No";s:5:"MS-89";s:10:"Mass range";s:14:"1.5 ~ 1000 amu";s:26:"Ion – source temperature";s:19:"100 °C ~ 350 °C";s:27:"GC-MS interface temperature";s:7:"450 °C";s:9:"Scan rate";s:16:"Upto 10000 amu/s";s:9:"Stability";s:21:"± 0.10 amu / 48 hrs.";s:25:"Filament emission current";s:11:"0 ~ 350 µA";s:27:"EI source ionization energy";s:13:"5 eV ~ 250 eV";s:10:"Resolution";s:15:"Unit resolution";s:8:"Detector";s:38:"High energy dynode electron multiplier";s:11:"Sensitivity";s:33:"Full scan ( S / N is ≥ 30 : 1 )";s:6:"Vacuum";s:31:"Turbo molecular pump ( 67 L/s )";}