Analytical HPLC 37-AHP101

Analytical HPLC 37-AHP101

Analytical HPLC system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyzes sample’s absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time.

Pump Specifications
Model No HPP-B1
Flow rate range 0.0001 ~ 10 ml / min
Maximum pressure 42 MPa , 0 ~ 5 ml / min
Column size 4.6 x 250 mm11
Sample size 5 µm
Pressure pulsation ≤ 1.5 % at 10 MPa
Flow rate accuracy ± 0.2 % at 1 ml / min
Flow rate repeatability % ≤ 0.15
Gradient accuracy % ± 2
Gradient repeatability % ≤ 0.2
Dimension 450 x 260 x 190 mm
Power supply 90 V ~ 240 V
Weight 11.2 kg
Detector Specifications
Model No HPD-B2
Wavelength range 190 to 800 nm
Wavelength accuracy ± 0.75 nm
Wavelength repeatability 0.2nm
Band width 8 nm
Optical path 10 nm
Deuterium lamp 190 ~ 400 nm
Tungsten lamp 400 ~ 800 nm
Baseline noise ( Static ) Au ≤ ± 0.5 x 10 -5
Baseline drift ( Static ) Au / h ≤ 1.5 x 10 -4
Minimum detection limit ≤ 4 x 10 -8
Power 100 W
Power supply 90 V / 50 ~ 60 Hz
Dimension 460 x 260 x 190 mm
Weight 9.2 kg
Autosampler Specifications
Model No ASI-B10
Syringe volume 1µl , 2.5 µl , 10 µl , 100 µl , 250 µl, 500 µl
Tray capacity ( removable rack ) 176 vials , 2 ml
Injection Speed 1 ~ 500 µl / s
Injection mode Full loop / partial loop
Analysis time 0 ~ 999 min
Wait time 12 s
RSD ( partial loop ) ≤ 0.5 %
RSD ( full loop ) ≤ 0.25 % ( typically ≤ 0.15 % )
Linearity ≥ 0.9999
Carry over ≤ 0.05 % ( with standard wash )
Power 55 W
Dimension 310 x 700 x 690 mm
Weight 15 kg
Standard Accessories
Accessory Quantity
Pump 2
UV-Vis detector ( without flow cell ) 1
Analytical flow cell 1
Injection valve 1
20 µl sample loop 1
4.6 x 250 mm ( 5µm ) analytical column 1
Solvent tray 1
Binary gradient kit 1
Mixing chamber 1
Optional Accessories
Accessory Quantity
Autosampler 1
Fraction collector 1
Column oven 1
  • Compression compensation ensuring gradient repeatability
    Low pressure gradient
    Detector ( Deuterium or tungsten lamp )
    Simultaneous working of deuterium and tungsten lamp
    Automatic sample injector ( Autosampler )
    External pump control by panel or computer software
    Auto save last detected records by the detector
    10 point calibration pump for linear pressure control
    Error alarm function for over pressure ,under pressure and leakage
  • Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis

Preparative HPLC

Preparative HPLC 37-PHP100

  • Dimension : 750 x 860 x 1280 mm ( 100 ml , 250 ml , 500 ml , 1000 ml ) , 810 x 950 x 1310 mm ( 3 L )
  • Wetted material : 316 L and PTFE

Semi-prep HPLC

Semi-prep HPLC 37-SPH100

  • Pump Specifications :
    Model No SPH-A10 SPH-A11 SPH-A12 SPH-A13
    Flow rate range 0.001 ~ 50 ml / min 0.001 ~ 50 ml / min 0.001 ~ 100 ml / min 0.001 ~ 100 ml / min
    Maximum pressure 30 MPa 30 MPa 15 MPa 10 MPa
    Flow rate accuracy ± 0.35 ± 0.5 ± 0.5 ± 0.5
    Flow rate repeatability % ≤ 0.1 ≤ 0.15 ≤ 0.1 ≤ 0.15
    Column size 10 x 250 mm 10 x 250 mm 10 x 250 mm 10 x 250 mm
    Sample loading 35 ~ 60 mg 35 ~ 60 mg 35 ~ 60 mg 35 ~ 60 mg
    Pressure pulsation 1 % at 10 MPa 1.5 % at 10 MPa 1.5 % at 10 MPa 1.5 % at 10 MPa
    Flow rate repeatability % ≤ 0.1 ≤ 0.15
    Gradient accuracy % ± 2 ± 2 ± 2 ± 2
    Gradient repeatability % ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2
    Dimension 465 x 315 x 180 mm 455 x 265 x 190 mm 465 x 315 x 180 mm 465 x 315 x 180 mm
    Power 150 W 150 W 150 W 150 W
    Power supply 90 V ~ 240 V/ 50 Hz 90 V ~ 240 V/ 60 Hz 90 V ~ 240 V/ 50 Hz 90 V ~ 240 V/ 60 Hz
    Weight 11.6 kg 11.2 kg 11.6 kg 11.6 kg
  • Detector Specifications :
    Model No SPH-A20 SPH-A21 SPH-A22
    Wavelength range 190 to 800 nm 190 to 800 nm 190 to 800 nm
    Wavelength accuracy ± 0.5 nm ± 1 nm ± 0.75 nm
    Wavelength repeatability 0.15 nm 0.3 nm 0.2 nm
    Band width 8 nm 8 nm 8 nm
    Optical path Semi flow / analytical Semi flow / analytical Semi flow / analytical
    Baseline noise ( Static ) Au ≤ ± 0.35 x 10 -5 ≤ ± 0.5 x 10 -5 ≤ ± 0.5 x 10 -5
    Baseline drift ( Static ) Au / h ≤ 1 x 10 -4 ≤ 1.5 x 10 -4 ≤ 1.5 x 10 -4
    Minimum detection limit ≤ 4 x 10 -8 ≤ 4 x 10 -8 ≤ 4 x 10 -8
    Power 150 W 150 W 150 W
    Power supply 90 V / 50 ~ 60 Hz 90 V / 50 ~ 60 Hz 90 V / 50 ~ 60 Hz
    Dimension 465 x 315 x 180 mm 465 x 315 x 180 mm 460 x 265 x 190 mm
    Weight 9.5 kg 9.5 kg 9.2 kg

Standard HPLC