Semi-prep is equipped with 4 sets of high pressure pumps providing a flow rate variance of 50 ml / min or 100 ml / min and a UV-Vis detector with a wavelength range of 190 to 800 nm. Equipped with a mixing chamber to enhance homogenization and reciprocating pump for consistent flow. With a column size of 10 x 250 mm and particle size of 5 µm or 10 µm, the retention, resolution and selectivity is optimized.
| Accessory | Quantity |
| Autosampler | 1 |
| Fraction collector ( 144 tubes , 12 mm test tubes ) | 1 |
| Fraction valve ( 6 channel ) | 1 |
| Model No | HPP-A1 |
| Flow rate range | 0.0001 ~ 10 ml / min |
| Maximum pressure | 50 MPa , 0 ~ 2 ml / min |
| Column size | 4.6 x 250 mm11 |
| Sample size | 5 µm |
| Pressure pulsation | ≤ 1 % at 10 MPa |
| Flow rate accuracy | ± 0.15 % at 1 ml / min |
| Flow rate repeatability % | ≤ 0.1 |
| Gradient accuracy % | ± 1.5 |
| Gradient repeatability % | ≤ 0.2 |
| Dimension | 460 x 310 x 180 mm |
| Power supply | 90 V |
| Weight | 11.6 kg |
| Model No | HPD-A20 | HPD-A21 |
| Wavelength range | Single wavelength ( 190 to 800 nm ) | Dual wavelength ( 190 to 800 nm ) |
| Wavelength accuracy | ± 0.5 nm | ± 2 nm |
| Wavelength repeatability | 0.15 nm | 0.3 nm |
| Band width | 8 nm | 8 nm |
| Optical path | 10 nm | 10 nm |
| Deuterium lamp | 190 ~ 400 nm | 190 ~ 400 nm |
| Tungsten lamp | 400 ~ 800 nm | 400 ~ 800 nm |
| Baseline noise ( Static ) Au | ≤ ± 0.35 x 10 -5 | ≤ ± 0.5 x 10 -5 |
| Baseline drift ( Static ) Au / h | ≤ 1 x 10 -4 | ≤ 1.5 x 10 -4 |
| Minimum detection limit | ≤ 4 x 10 -8 | ≤ 4 x 10 -8 |
| Power | 100 W | 100 W |
| Power supply | 90 V / 50 ~ 60 Hz | 90 V / 50 ~ 60 Hz |
| Dimension | 460 x 315 x 180 mm | 460 x 315 x 180 mm |
| Weight | 9.5 kg | 9.5 kg |
| Model No | HPP-B1 |
| Flow rate range | 0.0001 ~ 10 ml / min |
| Maximum pressure | 42 MPa , 0 ~ 5 ml / min |
| Column size | 4.6 x 250 mm11 |
| Sample size | 5 µm |
| Pressure pulsation | ≤ 1.5 % at 10 MPa |
| Flow rate accuracy | ± 0.2 % at 1 ml / min |
| Flow rate repeatability % | ≤ 0.15 |
| Gradient accuracy % | ± 2 |
| Gradient repeatability % | ≤ 0.2 |
| Dimension | 450 x 260 x 190 mm |
| Power supply | 90 V ~ 240 V |
| Weight | 11.2 kg |
| Model No | HPD-B2 |
| Wavelength range | 190 to 800 nm |
| Wavelength accuracy | ± 0.75 nm |
| Wavelength repeatability | 0.2nm |
| Band width | 8 nm |
| Optical path | 10 nm |
| Deuterium lamp | 190 ~ 400 nm |
| Tungsten lamp | 400 ~ 800 nm |
| Baseline noise ( Static ) Au | ≤ ± 0.5 x 10 -5 |
| Baseline drift ( Static ) Au / h | ≤ 1.5 x 10 -4 |
| Minimum detection limit | ≤ 4 x 10 -8 |
| Power | 100 W |
| Power supply | 90 V / 50 ~ 60 Hz |
| Dimension | 460 x 260 x 190 mm |
| Weight | 9.2 kg |