Pocket Conductivity tester  25-PCT102

Pocket Conductivity tester 25-PCT102

Pocket Conductivity tester is equipped with platinum sensor & 1 point push button calibration system. The easy to use pocket conductivity meter comes with waterproof features design for protection against harsh conditions. Conductivity meter on the basis of its low, mid and high conductivity measurement range can be used for measuring conductivity of drinking water, waste water, brine water and liquids with high, low conductivity.

Conductivity measurement range 0.1 to 19.99 mS/cm
Type of conductivity High range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity calibration solutions 12.88 mS/cm
Sensor type Platinum sensor
Temperature compensation 0 °C - 50 °C
Temperature coefficient 2 % per °C
Cell constant K=1
Normalization temperature 25 °C
Data hold function Manual
Display LCD screen
Power off Manual or automatic (8 minutes after last key is pressed)
Power 3 × 1.5 V “G134” batteries
Battery life Approximately 150 hours
Dimension (L*dia.) 185 × 40 mm
Weight 100 g
  • Equipped with platinum sensor
    High conductivity range
    1 point push button calibration to adjust the display value to known standard
    Auto hold function freezes stable, final readings for better viewing and recording
    Automatic temperature compensation for accurate measured value over the entire range
    Automatic power off helps to reduce battery power consumption
    Waterproof features guarantees protection against harsh conditions
    Replaceable electrode module to reduce the maintenance , replacement cost
  • 146.5 µS/cm, 1413 µS/cm, 12.88 mS/cm conductivity standard solutions
    G134 batteries
    Carrying box
  • 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm conductivity standard solutions
    Platinum conductivity electrode
  • Pocket Conductivity tester on the basis of its low, mid and high conductivity measurement range can be used for testing conductivity of pure water, drinking water , waste water, brine solutions and liquids.

Benchtop Conductivity Meter

Benchtop conductivity meter 25-BCM100

  • Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy : ± 1 % F.S.

Benchtop conductivity meter 25-BCM101

  • Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy : ± 1 % F.S.

Benchtop Dissolved oxygen meter

Benchtop Dissolved oxygen meter 25-BDO100

  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg / L

Benchtop Dissolved oxygen meter 25-BDO101

  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.2 mg / L

Benchtop Ion Meter

Benchtop Water hardness meter

Benchtop Water hardness meter 25-BWH100

  • Water hardness range : 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy : ± 1 % F.S.

Dissolved Oxygen tester

Pocket Dissolved oxygen tester 25-PDO100

  • Dissolved oxygen range : 0.0 to 20.0 mg/L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg/L

Multi-parameter water quality Analyzer

Multi parameter water quality analyzer 25-MWA100

  • COD : a:11:{s:23:"COD determination range";s:16:"2 to 10000 mg/ L";s:24:"COD measurement accuracy";s:61:"COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %";s:27:"COD minimum detection limit";s:9:"0.1 mg/ L";s:20:"COD measurement time";s:10:"20 minutes";s:17:"COD repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:0:"";s:44:"Consumables for colorimetric COD measurement";s:30:"Colorimetric tubes and Cuvette";s:33:"COD reactor digestion temperature";s:14:"165 ± 0.5°C";s:26:"COD reactor digestion time";s:6:"10 min";s:33:"COD reactor time setting switches";s:5:"3 pcs";s:26:"Anti-chlorine interference";s:27:"(Cl) < 1000 mg/ L No effect";}
  • Ammonia nitrogen : a:8:{s:36:"Ammonia nitrogen determination range";s:16:"0.02 to 60 mg/ L";s:37:"Ammonia nitrogen measurement accuracy";s:11:"≤ ± 10 %";s:40:"Ammonia nitrogen minimum detection limit";s:10:"0.01 mg/ L";s:33:"Ammonia nitrogen measurement time";s:16:"10 to 15 minutes";s:30:"Ammonia nitrogen repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:0:"";s:57:"Consumables for colorimetric ammonia nitrogen measurement";s:30:"Colorimetric tubes and Cuvette";s:46:"Ammonia nitrogen reactor time setting switches";s:5:"3 pcs";}

Multi parameter water quality analyzer 25-MWA101

  • COD : a:11:{s:23:"COD determination range";s:15:"5 to 5000 mg/ L";s:24:"COD measurement accuracy";s:61:"COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %";s:27:"COD minimum detection limit";s:9:"0.1 mg/ L";s:20:"COD measurement time";s:10:"20 minutes";s:17:"COD repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:6:"12 pcs";s:44:"Consumables for colorimetric COD measurement";s:30:"Colorimetric tubes and Cuvette";s:33:"COD reactor digestion temperature";s:14:"165 ± 0.5°C";s:26:"COD reactor digestion time";s:6:"10 min";s:33:"COD reactor time setting switches";s:5:"3 pcs";s:26:"Anti-chlorine interference";s:27:"(Cl) < 1000 mg/ L No effect";}
  • Ammonia nitrogen : a:8:{s:36:"Ammonia nitrogen determination range";s:16:"0.02 to 30 mg/ L";s:37:"Ammonia nitrogen measurement accuracy";s:11:"≤ ± 10 %";s:40:"Ammonia nitrogen minimum detection limit";s:10:"0.01 mg/ L";s:33:"Ammonia nitrogen measurement time";s:16:"10 to 15 minutes";s:30:"Ammonia nitrogen repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:6:"20 pcs";s:57:"Consumables for colorimetric ammonia nitrogen measurement";s:30:"Colorimetric tubes and Cuvette";s:46:"Ammonia nitrogen reactor time setting switches";s:5:"3 pcs";}

ORP tester

Pocket ORP tester 25-POT100

  • Sensor type : Platinum sensor
  • Connector : 6 pin

Pocket ORP tester 25-POT101

  • Connector : BNC
  • ORP measurement range : (-999) to 999 mV

pH Meter (Benchtop)

pH Tester (POCKET)

Portable dissolved oxygen meter

Portable Dissolved oxygen meter 25-PDM100

  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg / L

Portable Dissolved oxygen meter 25-PDM101

  • Dissolved oxygen range : 0.0 - 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.2 mg / L

Portable Multi Parameter Water Quality Meter

pH Meter (Portable)

Portable pH meter 25-PPM100

  • pH range : (-2.00) to 16.00 pH
  • pH accuracy : ± 0.01 pH

Portable pH/ORP meter 25-PPM101

  • pH range : (-2.00) to 20.00 pH
  • pH accuracy : ± 0.002 pH

Portable water hardness meter

Portable water hardness meter 25-PHM100

  • Water hardness range : 0.05 mmol / L - 0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy : ± 1 % F.S.

Salinity Tester

Pocket Salinity tester 25-PST100

  • Salinity measurement range : 0.00 to 10.00 ppt
  • Salinity accuracy : ± 1 % F.S

Pocket Salinity tester 25-PST101

  • Salinity measurement range : 0.00 to 80.00 ppt
  • Salinity accuracy : ± 1 % F.S

TDS tester

Turbidity Meter

Enquiry Form
Captcha Image