Portable Dissolved oxygen meter  25-PDM100

Portable Dissolved oxygen meter 25-PDM100

Portable Dissolved oxygen meter is equipped with polarographic sensor to measure the dissolved oxygen content. The manual salinity & barometric pressure compensation helps in accurate measurement of dissolved oxygen. It can store up to 48 sets of data & it is transferrable to PC via USB interface. Due to its portable nature this meter can be used across water purification plants, waste water management plants for testing & quality analysis.

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Calibration points 1 - 2 points
Sensor type Polarographic DO probe
Temperature compensation range 0 to 40 °C, 32 °F to 104 °F
Barometric pressure correction 60.0 to 112.5 kPa, 450 to 850 mmHg
Salinity correction 0 - 35 g / L
% of saturation of oxygen range 0.0 to 200.0 %
% of saturation of oxygen accuracy ± 10 % F.S.
% of saturation of oxygen resolution 0.001
Data hold function Manual
Reset function Yes
Memory Stores up to 48 sets of data
Output USB communication interface
Display LCD screen
Connector 4-pin mini plug
Battery life Approximately 150 hours
Power 1 x 9 V / 800 mA battery
Dimension (L x W x H) 185 × 88 × 32 mm
Weight 300 g
  • Equipped with polarographic sensor & LCD display
    1-2 points calibration using air saturated water & zero oxygen solution
    Manual salinity & barometric pressure compensation for better measurement of dissolved oxygen
    Stores up to 48 sets of data
    Data is transferrable to PC via USB interface
    Built-in real time clock stamps stores data to meet GLP standard
    Automatic temperature compensation for accurate measured value over the entire range
    Auto hold function freezes stable, final readings for better viewing and recording
    Reset function automatically resumes all the settings to default mode
    Help message as an operational guide for quick beginning to the dissolved oxygen meter
  • Dissolved oxygen probe
    Dissolved oxygen Electrolyte solution
    Membrane cap
    1 x 9 V/ 800 mA battery
    Carrying case
  • Polarographic sensor
    30 mL electrolyte solution per bottle
    Membrane cap
  • Portable dissolved oxygen meter has applications in water & waste water management industry, environmental monitoring, surface ground water, research & development, education to detect content of dissolved oxygen.

Benchtop Conductivity Meter

Benchtop conductivity meter 25-BCM100

  • Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy : ± 1 % F.S.

Benchtop conductivity meter 25-BCM101

  • Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
  • Conductivity accuracy : ± 1 % F.S.

Benchtop Dissolved oxygen meter

Benchtop Dissolved oxygen meter 25-BDO100

  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg / L

Benchtop Dissolved oxygen meter 25-BDO101

  • Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
  • Dissolved oxygen accuracy : ± 0.2 mg / L

Benchtop Ion Meter

Benchtop Water hardness meter

Benchtop Water hardness meter 25-BWH100

  • Water hardness range : 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy : ± 1 % F.S.

Conductivity Tester

Pocket Conductivity tester 25-PCT100

  • Conductivity measurement range : 1.0 to 199.9 µS/cm
  • Type of conductivity : Low range conductivity

Pocket Conductivity tester 25-PCT101

  • Conductivity measurement range : 10 to 1999 µS/cm
  • Type of conductivity : Mid-range conductivity

Pocket Conductivity tester 25-PCT102

  • Conductivity measurement range : 0.1 to 19.99 mS/cm
  • Type of conductivity : High range conductivity

Dissolved Oxygen tester

Pocket Dissolved oxygen tester 25-PDO100

  • Dissolved oxygen range : 0.0 to 20.0 mg/L (or ppm)
  • Dissolved oxygen accuracy : ± 0.5 mg/L

Multi-parameter water quality Analyzer

Multi parameter water quality analyzer 25-MWA100

  • COD : a:11:{s:23:"COD determination range";s:16:"2 to 10000 mg/ L";s:24:"COD measurement accuracy";s:61:"COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %";s:27:"COD minimum detection limit";s:9:"0.1 mg/ L";s:20:"COD measurement time";s:10:"20 minutes";s:17:"COD repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:0:"";s:44:"Consumables for colorimetric COD measurement";s:30:"Colorimetric tubes and Cuvette";s:33:"COD reactor digestion temperature";s:14:"165 ± 0.5°C";s:26:"COD reactor digestion time";s:6:"10 min";s:33:"COD reactor time setting switches";s:5:"3 pcs";s:26:"Anti-chlorine interference";s:27:"(Cl) < 1000 mg/ L No effect";}
  • Ammonia nitrogen : a:8:{s:36:"Ammonia nitrogen determination range";s:16:"0.02 to 60 mg/ L";s:37:"Ammonia nitrogen measurement accuracy";s:11:"≤ ± 10 %";s:40:"Ammonia nitrogen minimum detection limit";s:10:"0.01 mg/ L";s:33:"Ammonia nitrogen measurement time";s:16:"10 to 15 minutes";s:30:"Ammonia nitrogen repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:0:"";s:57:"Consumables for colorimetric ammonia nitrogen measurement";s:30:"Colorimetric tubes and Cuvette";s:46:"Ammonia nitrogen reactor time setting switches";s:5:"3 pcs";}

Multi parameter water quality analyzer 25-MWA101

  • COD : a:11:{s:23:"COD determination range";s:15:"5 to 5000 mg/ L";s:24:"COD measurement accuracy";s:61:"COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %";s:27:"COD minimum detection limit";s:9:"0.1 mg/ L";s:20:"COD measurement time";s:10:"20 minutes";s:17:"COD repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:6:"12 pcs";s:44:"Consumables for colorimetric COD measurement";s:30:"Colorimetric tubes and Cuvette";s:33:"COD reactor digestion temperature";s:14:"165 ± 0.5°C";s:26:"COD reactor digestion time";s:6:"10 min";s:33:"COD reactor time setting switches";s:5:"3 pcs";s:26:"Anti-chlorine interference";s:27:"(Cl) < 1000 mg/ L No effect";}
  • Ammonia nitrogen : a:8:{s:36:"Ammonia nitrogen determination range";s:16:"0.02 to 30 mg/ L";s:37:"Ammonia nitrogen measurement accuracy";s:11:"≤ ± 10 %";s:40:"Ammonia nitrogen minimum detection limit";s:10:"0.01 mg/ L";s:33:"Ammonia nitrogen measurement time";s:16:"10 to 15 minutes";s:30:"Ammonia nitrogen repeatability";s:10:"≤ ± 5 %";s:41:"Processing sample number per batch";s:6:"20 pcs";s:57:"Consumables for colorimetric ammonia nitrogen measurement";s:30:"Colorimetric tubes and Cuvette";s:46:"Ammonia nitrogen reactor time setting switches";s:5:"3 pcs";}

ORP tester

Pocket ORP tester 25-POT100

  • Sensor type : Platinum sensor
  • Connector : 6 pin

Pocket ORP tester 25-POT101

  • Connector : BNC
  • ORP measurement range : (-999) to 999 mV

pH Meter (Benchtop)

pH Tester (POCKET)

Portable Multi Parameter Water Quality Meter

pH Meter (Portable)

Portable pH meter 25-PPM100

  • pH range : (-2.00) to 16.00 pH
  • pH accuracy : ± 0.01 pH

Portable pH/ORP meter 25-PPM101

  • pH range : (-2.00) to 20.00 pH
  • pH accuracy : ± 0.002 pH

Portable water hardness meter

Portable water hardness meter 25-PHM100

  • Water hardness range : 0.05 mmol / L - 0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
  • Accuracy : ± 1 % F.S.

Salinity Tester

Pocket Salinity tester 25-PST100

  • Salinity measurement range : 0.00 to 10.00 ppt
  • Salinity accuracy : ± 1 % F.S

Pocket Salinity tester 25-PST101

  • Salinity measurement range : 0.00 to 80.00 ppt
  • Salinity accuracy : ± 1 % F.S

TDS tester

Turbidity Meter

Enquiry Form
Captcha Image